Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
BioMicro Center
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
BioMicroCenter:Covaris
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Special pages
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
= COVARIS = == E220 Evolution == The [https://www.covaris.com/e220evolution-focused-ultrasonicator-500429/ Covaris E220 evolution sonicator] is a multitube system developed for high performance sample preparation. The E220evolution is capable of processing a wide range of sample types and volumes and may be programed to process from 1 to 96 samples in a single batch. The E220 is most appropriate <5ug clean DNA in 130ul (microTUBE-130) or 20-120 mg tissue mass in 1.0 ml (milliTUBE-1). Using adaptive focused acoustic energy, the E220 utilizing a spherical acoustic transducer, and delivers controlled energy precisely and accurately to sample volumes from 25 μl to 10 ml. The main applications are shearing of DNA, RNA, and chromatin but it can also perform tissue homogenization for cell lysis and drug delivery and formulation. <BR><BR> [https://www.covaris.com/protocols?filter_tag=DNA%20Shearing%20Protocols/ DNA] or [https://www.covaris.com/protocols?filter_tag=Chromatin%20Shearing%20Protocols/ Chromatin, FFPE] etc., protocols for optimizing the sonication time for next generation sequencing can be found on the company's website: [https://www.covaris.com/ Covaris] <br><br> The manual can be found here: [https://www.covaris.com/e220evolution-focused-ultrasonicator-500429/ E220 evolution]. <br> [[Image:E220.jpg|thumb|right|250px| Covaris E220 Evolution]] [[Image:Covaris_part.jpeg|thumb|right|125px| Water Chiller Unit]] [[Image:Covaris_water_filter.jpeg|thumb|right|125px| Water Filtering Unit]] <br><br> MAINTENANCE <br> (BE CAREFUL WITH the ACOUSTIC ASSEMBLY LENS, REPORT IMMEDIATELY if SHARPS (like broken glass) GOT ONTO IT) <br><br> Two types of maintenance after Covaris use: <br> Case#1. Covaris was connected to working water-filtering unit; <br> Case#2. Covaris was not connected to water-filtering unit (hosing is taken off, water-filtering unit is switched "OFF". <br><br> Maintenance Case#1(usually, water-filtering is set up for multiple Covaris usage, degas-ready for all subsequent runs, after the 1st) <br><br> After your run is finished - a pop-up alert will appear on the computer screen. <br> (1)-Click "OK", then <br> (2) click "Load" button to move the holder to "Load" position, <br> (3) take the rack containing your samples out of COVARIS chamber, <br> (4) close the chamber, <br> (5) switch off the chiller unit (underneath the Covaris) <br> (6) click "Service" button to raise the Sample Holder and Acoustic Assembly above the water bath. Degas pump will stop. <br> (7) Quit COVARIS software, check that the tubing connectors of COVARIS (front panel) to water-filtering unit (front panel) are not leaking any water, <br> (8) clean the area around the machine, wipe off any water spills. <br> (9) Optional: turn the Covaris "OFF" (switch is on the right side of the machine), - lights inside the machine will go off,- after you press the switch. <br> (10)Optional: Switch the water-filtering unit "ON"(right side of the Covaris Instrument) <br><br> Maintenance Case#2 <br> If you used Covaris without connection to Water-Filtering Unit - you must empty water bath after use. <br><br> (A) Follow the instructions for Case#1 to the step (6)("Sevice Position"). It raises the acoustic assembly above water bath and enables it;' removal <br> (B) Gently and carefully pull out (towards you) the plexiglass bath of Covaris (currently filled with water) - and empty it into the sink, then - reinstall the bath. <br> (C) re-install the empty bath, click "load position": the acoustic assembly will go down <br> (D) temporarily, for few seconds, switch the degas pump "ON": it will purge some extra water out into the bath - and stop. If not stopped in 10s - click "degas OFF" <br> (E) Quit the Covaris software and turn off the Covaris machine (upper-right side button. Make sure the Chiller Unit and Filtering unit are OFF. Cleanup any spills <br><br> The Covaris service is now complete. == R230 == [[IMAGE:R230pic.jpeg|right|350px|R230 Focused ultrasonicator 1.0 (not pictured: eBox and WCS 3.0)]] <br><br> The Covaris R230 is fitted for 96 AFA-TUBE® TPX Plates. Both RNA and DNA have been sheared with similar programs to the ones found on the E220 Evolution at maximum input 5 ug 20-50 uL per well in the sonication by column mode. With this column sonication mode, an entire 96 well plate can be sonicated 10x faster in the R230 versus the E220. A scanning mode exists but has not been tested yet. There are accessories to utilize both 8-well strips and 384 well plates, but these accessories have not been acquired.
Summary:
Please note that all contributions to BioMicro Center may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
BioMicro Center:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)