Element Sequencing[edit]

The Center currently hosts an AVITI24 platform from Element Biosciences. AVITI24 platform supports both sequencing and cytoprofiling. For most sequencing needs, the Center will use Element's Freestyle chemistry kits.

Service Element Sequencing
SUBMISSION Illumina OR Element libraries
MIN VOLUME 15 uL
MIN CONCENTRATION 2 nM
INCLUDED SERVICES
  • Quality Control:Fragment Analyzer and qPCR
  • Element Sequencing
  • Demultiplexing
ADDITIONAL SERVICES
  • Quality Control
  • Element library preperation
DATA FORMATS
  • FASTQ (stored 1 year)
QUALITY CONTROL
  • FASTQC
  • Basic run metrics (alignment rate, complexity)
  • Basic RNAseq metrics (where applicable)
  • Basic paired end metrics (where applicable)
  • Contamination checks
PRICING LINK
SUBMISSION

P5/P7 anchored library (Illumina) is preferred. Element Adept libraries (SP5/SP27) require a 5'-phosphate on the forward end in order to circularize and sequence. Compared to an Illumina platform, AVITI24 reads are similar in read direction to Illumina's Forward Strand workflow for Dual Indexed Libraries.

Minimum reads per lane are guaranteed if:

  • the BMC has performed quality control,
  • the samples have high diversity, especially within the first 5 bases of read 1, and
  • submitted libraries are at least 2 nM.

Lane-by-lane Notes[edit]

  • The wait is variable
  • Custom primers must be compatible with TruSeq, Nextera, TruSeq, smRNA and Element sequencing primers

All other requests require a full flowcell. 300PE kits only have a single lane.

  • Min custom primer submission: 70 uL at 100 uM for Read 1, all other reads require 40 uL at 100 uM.

The AVITI24 Platform[edit]

AVITI24 NOTES
SEQUENCER
READS/FLOWCELL
Low number is minimum per lane for standard P5/P7 libraries.
  • 250M HQ read pairs (150 for PE300)
RUN TIME
  • 75 PE 24 hours
  • 150 PE 38 hours
  • 300 PE 60 hours
KITS AVAILABLE
  • 2x75 Cloudbreak FS High
  • 2x150 Cloudbreak FS High
  • 2x300 Cloudbreak FS High
- Single end supported
- each kit comes with 34 additional cycles
KEY NOTES
  • 4-color chemistry
  • Random flow cell
  • 2-lanes per flow cell (1 for 300PE)
  • Q40+ > 80%
  • Low-binding surface chemistry
THANKS TO
  • Element Biosciences / Scott Ritterbush


The AVITI24 can run 2 flow cells per run, each hosting 2 independently-addressable lanes. Both lanes are washed with the same reagents. Element currently offers kits with 150 and 300 cycles, both supporting 2 lanes, as well as a 600 cycle kit that supports a single lane. Index hopping rates are similar to non-patterned Illumina, limiting the need for UDI's. The AVITI24 can also perform direct in sample sequencing which includes spatial imaging of RNA, proteins, phospho-proteins, and cell morphology using Teton chemistry for cytoprofiling.