BioMicroCenter:Singular Sequencing: Difference between revisions
No edit summary |
|||
(55 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
== Singular Sequencing == | |||
The Center currently hosts a G4 platform by [https://singulargenomics.com/| Singular Genomics]. Singular’s G4 platform is a short-read mid-throughput sequencing platform delivering adequate sequencing data through its proprietary sequencing-by-synthesis chemistry at a significantly competitive price point. | |||
{| class="wikitable" border=1 | |||
!width=100| Service | |||
!Service | !width=250| Singular Sequencing | ||
!Singular Sequencing | |||
|- | |- | ||
|INPUT || | |INPUT || Singular libraries | ||
|- | |- | ||
|MIN VOLUME || 12 uL | |MIN VOLUME || 12 uL | ||
Line 20: | Line 19: | ||
|ADDITIONAL SERVICES || | |ADDITIONAL SERVICES || | ||
* Quality Control | * Quality Control | ||
* Singular library | * Singular library preparation | ||
|- | |- | ||
|DATA FORMATS | |DATA FORMATS | ||
| | | | ||
*FASTQ (stored 1 year) | *FASTQ (stored 1 year) | ||
|- | |- | ||
|QUALITY CONTROL | |QUALITY CONTROL | ||
Line 43: | Line 41: | ||
|} | |} | ||
Compared to a typical Illumina library, a Singular index 1 would be the reverse compliment of the i5 index, whereas index 2 would be the reverse compliment of the i7 index. | |||
=== | ===Lane-by-lane Requirements=== | ||
*Must be 50 or 150 paired-end dual indexed | |||
*Pool must be compatible with TruSeq, Nextera, TruSeq, smRNA and Solexa sequencing primers | |||
Minimum reads per lane are guaranteed if: | |||
*the BMC has performed quality control, | |||
*the samples are high-complexity, especially for the first 10 nt of read 1, and | |||
*submitted libraries are at least 2 nM. | |||
< | |||
All other requests, including use of custom sequencing primers require a full flowcell. Illumina libraries which have been converted in the Center will also require a full flowcell. | |||
*Min custom primer submission: 20 uL at 100 uM | |||
[[IMAGE:IndexhopF3.jpeg|left|250px|Index hopping for a standard set of Singular libraries]] [[IMAGE:PPPPF3.jpeg|right|200px|Percent Perfect Plot for Singular libraries 150PE]] | |||
Index hopping on Singular runs has been low. The performance of an F3 flowcell mimics other short-read 4 color chemistry sequencers with patterned flowcells. | |||
<br><br><br><br> | |||
=== | == The G4 Platform == | ||
== | {| class="wikitable" border=1 | ||
!width=100| SPEC | |||
!width=250| G4 | |||
|- | |||
|'''SEQUENCER'''||[[Image:2023_Singular_G4.jpg|center|200px]] | |||
|- | |||
| '''READS/LANE'''<BR> Low number is minimum per lane for standard libraries|| | |||
* F3 per Lane: 50-100 M | |||
|- | |||
|'''RUN TIME'''|| | |||
* 50 PE 11 hours | |||
* 150 PE 24 hours | |||
|- | |||
|'''KITS AVAILABLE'''|| | |||
* 100nt | |||
* 300nt | |||
|- | |||
|'''KNOWN APPLICATIONS'''|| | |||
* RNAseq including single cell | |||
* Gene Expression | |||
* Exome | |||
* Target Enrichment | |||
* Metagenomics | |||
|- | |||
|'''KEY NOTES'''|| | |||
* 4-color chemistry | |||
* Patterned flow cell | |||
* 4-lanes per flow cell | |||
* 4-flow cells per run | |||
* Index replacement or anchor expansion of Illumina libraries | |||
|- | |||
|'''THANKS TO'''|| | |||
* Singular Genomics | |||
|} |
Latest revision as of 17:26, 9 June 2025
Singular Sequencing[edit]
The Center currently hosts a G4 platform by Singular Genomics. Singular’s G4 platform is a short-read mid-throughput sequencing platform delivering adequate sequencing data through its proprietary sequencing-by-synthesis chemistry at a significantly competitive price point.
Service | Singular Sequencing |
---|---|
INPUT | Singular libraries |
MIN VOLUME | 12 uL |
MIN CONCENTRATION | 4 nM |
INCLUDED SERVICES |
|
ADDITIONAL SERVICES |
|
DATA FORMATS |
|
QUALITY CONTROL |
|
PRICING | LINK |
SUBMISSION |
|
Compared to a typical Illumina library, a Singular index 1 would be the reverse compliment of the i5 index, whereas index 2 would be the reverse compliment of the i7 index.
Lane-by-lane Requirements[edit]
- Must be 50 or 150 paired-end dual indexed
- Pool must be compatible with TruSeq, Nextera, TruSeq, smRNA and Solexa sequencing primers
Minimum reads per lane are guaranteed if:
- the BMC has performed quality control,
- the samples are high-complexity, especially for the first 10 nt of read 1, and
- submitted libraries are at least 2 nM.
All other requests, including use of custom sequencing primers require a full flowcell. Illumina libraries which have been converted in the Center will also require a full flowcell.
- Min custom primer submission: 20 uL at 100 uM


Index hopping on Singular runs has been low. The performance of an F3 flowcell mimics other short-read 4 color chemistry sequencers with patterned flowcells.