BioMicroCenter:SingleCell: Difference between revisions
No edit summary |
|||
(7 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{BioMicroCenter}} | {{BioMicroCenter}} | ||
The BioMicro Center supports | The BioMicro Center supports two technologies for single cell experiments: 10X libraries as walkup or as an assisted service, and plate based methods using the Namocell single cell sorter. <BR><BR> | ||
== | <!-- commenting out Seq-Well | ||
== SEQ-WELL == | |||
{| | {| | ||
|- style="vertical-align: top;" | |- style="vertical-align: top;" | ||
Line 9: | Line 10: | ||
{| class="wikitable" border=1 | {| class="wikitable" border=1 | ||
! | ! | ||
! | !SEQ-WELL | ||
|- | |- | ||
|INPUT | |INPUT | ||
Line 33: | Line 34: | ||
|} | |} | ||
| | | | ||
The BioMicro Center collaborates closely with the Nanowell Core in the Koch Institute to provide support for the | The BioMicro Center collaborates closely with the Nanowell Core in the Koch Institute to provide support for the [https://shaleklab.com/resources/seq-well/ Seq-Well] protocol developed by Drs. Alex Shalek and Chris Love's groups. Seq-Well is based on the isolation of individual cells into microwells where cells are lysed and the associated mRNA is attached to polydT containing beads. <BR><BR> | ||
Seq-Well projects can be brought in two ways. For full service, please use the ilabs form linked on the left. At the end of the form it asks you to select several days on which the experiment can be done. The Nanowell Core will review the possible dates with you to fit it in the schedule. On that date, the core will confirm the quality of your cells prior to beginning the experiment. While 10,000 cells are typically used in a Seq-Well experiment, the core requests you plan to bring more cells - often counts from flow cytometers and other instruments are incorrect. Planning to bring more cells ensures you have the 10,000 desired. The BioMicro Center becomes involved in these projects at the exonuclease treatment step, where we take over the preparation of the library and quality control, as well as sequencing and analysis.<BR><BR> | |||
Many laboratories are also using reagents from the Nanowell core to begin doing | Many laboratories are also using reagents from the Nanowell core to begin doing Seq-Well on their own. For these labs, we strongly recommend at least confirming the quality of the cDNA on our Advanced Analytical before continuing through library preparation. The library preparation can also be done in the BioMicro Center. Please use the standard Illumina library preparation form and note that the samples are Seq-Well. We do have all the custom primers needed for preparation and the pricing is identical to other NexteraXT preps. | ||
|} | |} | ||
--> | |||
== 10x CHROMIUM X == | == 10x CHROMIUM X == | ||
{| | {| | ||
Line 130: | Line 131: | ||
| | | | ||
The [https://www.namocell.com/namo/ Namocell Single Cell Sorter] allows users to sort cells into plates. The sorter uses microfluidics to sort single cells in 1uL of sheath fluid into a well. The instrument uses disposable cartridges to minimize contamination. The instrument is expected to integrate well with the [[BioMicroCenter:Tecan_Freedom_Evo#TTP_LABTECH_MOSQUITO_HV|TTP Labtech Mosquito HV]] which handles small reaction volumes. <BR><BR> | The [https://www.namocell.com/namo/ Namocell Single Cell Sorter] allows users to sort cells into plates. The sorter uses microfluidics to sort single cells in 1uL of sheath fluid into a well. The instrument uses disposable cartridges to minimize contamination. The instrument is expected to integrate well with the [[BioMicroCenter:Tecan_Freedom_Evo#TTP_LABTECH_MOSQUITO_HV|TTP Labtech Mosquito HV]] which handles small reaction volumes. <BR><BR> | ||
[[image:Namo.jpg|thumb|right]] | |||
| | | | ||
|} | |} | ||
<!-- 100-10k 10c/" 1b/ml --> | <!-- 100-10k 10c/" 1b/ml --> |
Latest revision as of 14:58, 2 May 2025
The BioMicro Center supports two technologies for single cell experiments: 10X libraries as walkup or as an assisted service, and plate based methods using the Namocell single cell sorter.
10x CHROMIUM X[edit]
|
The BioMicro Center provides access to 10x Genomics library preparation as an assisted or a walk-up service. Added in 2023, The 10x Chromium X can handle a broad variety of methodologies now including 3' and 5' RNA sequencing, ATACseq and CNV. For users requesting assisted service, they will bring their single cell suspension to the core at a time coordinated with the center staff. We will then work with you to get the initial samples loaded and proceed through the protocol with a quality control check at the amplified cDNA state.
FAQs for Users For more resources, please visit https://kb.10xgenomics.com/hc/en-us |
NAMOCELL SINGLE CELL SORTER[edit]
|
The Namocell Single Cell Sorter allows users to sort cells into plates. The sorter uses microfluidics to sort single cells in 1uL of sheath fluid into a well. The instrument uses disposable cartridges to minimize contamination. The instrument is expected to integrate well with the TTP Labtech Mosquito HV which handles small reaction volumes. ![]() |