Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
BioMicro Center
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
BioMicroCenter:RTPCR Protocol for Sample QC
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Special pages
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{BioMicroCenter}} [[Image:BioMicroCenter-Cluster_numbers.png|600px|right]] This protocol is a slightly modified version of the protocol used at the Broad Institute. The original protocol was developed by Maura Costello. This protocol is similar to the one published in Nature Methods by Quail et al (2008) but uses SYBRgreen instead of Taqman probes. === Proof of Concept === Simultaneous test. Samples were tested for RT-PCR and clustered for sequencing on the same day. Their DNA concentration and the correlation of the concentration as measured by RT-PCR was then compared to their cluster number. All DNA samples had been thought to be at 10nM as determined by Qubit quantification. <br> [[Image:BioMicroCenter-QPCR_proof_of_concept.jpg|400px]] == Key Notes == * Use forward and reverse primers that match the 5' and 3' linkers used in the Illumina sample prep * DO NOT FREEZE your samples between preforming RT-PCR and loading the cluster station (they can be left at 4°C for up to 24 hours). * Standard curve created using serial dilution of PhiX control DNA * Standard curve must have a R^2 > 0.98 == Materials == * '''Enriched sample libraries (with either paired end or standard adapters)''' * '''Phix 335bp control library (Cat. No. CT-901-1001)''' * '''Qiagen Buffer EB''' * '''Molecular biology grade water''' * '''10uM Forward Primer: AATGATACGGCGACCACCGA''' * '''10uM Reverse Primer: CAAGCAGAAGACGGCATACGA''' * '''SYBR Green''' <span style="color: red">Roche LightCycler 480 SYBR Master Mix (Cat. No. 04707516001)</span><br> or <br> <span style="color: green">KAPA LightCycler 480 SYBR Fast Master Mix (Cat. No. KK4611)</span> * '''LightCycler Plate''' <span style="color: red">Roche LightCycler 480 Multiwell Plate 96, Clear (Cat No. 05102413001) and Sealing Foil</span><br> or<br> <span style="color: green">Axygen LightCycler 480 Multiwell Plate 96, White (Cat No. PCR-96-LC480-W) and Sealing Foil</span> == Preparing Standards == This procedure creates seven standards ranging from ~20nM to 0.3nM with which to create the standard curve. In preparing these standards 1:100 dilutions are created. After this step the standards are ready to use, they do not need to be diluted any further, and they can be kept at 4° for up to seven days. * S1 – add 2uL of Phix control to 198uL of EB (1:100) * S2 – add 50uL of S1 to 50uL of EB (1:200) * S3 – add 50uL of S2 to 50uL of EB (1:400) * S4 – add 50uL of S3 to 50uL of EB (1:800) * S5 – add 50uL of S4 to 50uL of EB (1:1600) * S6 – add 50uL of S5 to 50uL of EB (1:3200) * S7 – add 50uL of S6 to 50uL of EB (1:6400) Vortex '''well''' and spin down in between each dilution <span style="color: purple">Illumina Phix concentrations vary from lot to lot. It is recommended that you pool multiple tubes of Phix, separate them out into one time use aliquots (~2uL) and quantify one aliquot (we use the KAPA Library Quantification kit for qPCR). This will allow you to have consistent concentrations across multiple preparations of your standards.</span> == Preparing Samples == * Dilute all samples to ~10nM with EB using previous quantification (Bioanalyzer or Qubit are recommended). * Create 1:1000 stocks of each sample by adding 1uL of a 10nM sample to 999uL of EB. If a sample is suspected to be highly concentrated based off of previous quantification, do a 1:10,000 dilution by adding 1uL sample to 99uL EB, then 1uL of the diluted stock to 99uL of EB again. * Make sure to vortex well and spin down each sample <span style="color: purple">Having a rough idea of the concentrations of your samples helps to avoid loading samples that are too concentrated for the RT-PCR machine to read.</span> == Preparing Master Mix == Make the following reaction mix for each well being used. Keep in mind that each sample requires three wells (triplicates) and the 16 standard wells. '''For 1 well: Roche SYBR''' * Water – 3uL * PCR Primer Forward (P5), 10uM – 1uL * PCR Primer Reverse (P7), 10uM – 1uL * Roche SYBR Green – 10uL '''For 1 well: KAPA SYBR''' * Water – 7.2uL * PCR Primer Forward (P5), 10uM – 0.4uL * PCR Primer Reverse (P7), 10uM – 0.4uL * KAPA Sybr Fast – 10uL '''<span style="color: purple">Do not add SYBR Green to master mix until right before use. Flick and spin down master mix after SYBR green has been added</span> ''' <span style="color: red">Master mix may vary depending on type of RT-PCR machine and brand of SYBR green being used</span> == Plate Preparation == [[Image:BioMicro_RT_Final_plate_setup.jpg|600px]]<BR> Lanes 4 through 10 can be used for additional samples or left empty '''Plate set up:''' * For Roche SYBR, add 5uL of samples and standards to appropriate wells * Add 5uL of EB to wells H11 and H12 for negative controls * Add 15uL of Master Mix to each well * Apply sealing foil * Briefly spin plate down <br> <br> * For KAPA SYBR Fast, add 2uL of samples and standards to appropriate wells * Add 2uL of EB to wells H11 and H12 for negative controls * Add 18uL of Master Mix to each well * Apply sealing foil * Briefly spin plate down <span style="color: purple">We have found that the most effective way to load the plate is:</span> # prepare the samples and incomplete master mix (containing everything but SYBR green) # On ice, plate all of the samples and standards # Add SYBR green to master mix and then add complete master mix to all wells being used == RT-PCR Amplification Protocol == On the LightCycler, we have found that running 30 cycles of amplification is sufficient for library quantification using the Roche SYBR Green (35 cycles for KAPA SYBR) * Roche SYBR '''Activation:<br>''' 95°C - 5 minutes<br> '''Amplification:<br>''' 95°C – 5 seconds<br> 60°C – 10 seconds <span style="color: red">The annealing temp can vary, depending on melting temperature of each primer</span><br> 72°C – 30 seconds <br> '''Melting Curve:<br>''' 95°C - 5 seconds<br> 65°C - 1 minute<br> 97°C<br> '''Cooling: <br>''' 40°C - 30 seconds * KAPA SYBR '''Activation:<br>''' 95°C - 5 minutes<br> '''Amplification:<br>''' 95°C – 30 seconds<br> 60°C – 45 seconds <span style="color: red">1-step annealing/extension</span><br> == Result Analysis == When run is complete use standard Cp (cycle number at which the amplification curve crosses the threshold) analysis for the machine being used. <span style="color: red">If using LichtCycler 480 remember to change “High Confidence” to “High Sensitivity” in results page, this is to allow for a more stringent threshold for quantifying Illumina libraries.</span> Look over the amplification plots. If successful amplification has occurred you should see typical sinusoidal amplification for each plot. If the curves start below the 0 mark on the y-axis and appears to amplify around cycle 6, the sample is most likely too concentrated for the machine to accurately quantify the libraries. [[Image:BioMicro_Amp_graphs.jpg|700px]] ===Calculate the Standard Curve:=== * graph log concentration vs. Cp of your standards: [[Image:BioMicroCenter_RTPCR_std1.jpg|400px]] {|[[Image:BioMicro_Too_conc_ampl_plot.jpg|400px]]||[[Image:BioMicro_Standard_curve.jpg|400px|]]|} * The r^2 for the standard curve must be >0.98 or the RT-PCR should be repeated. Omit outliers as necessary. <span style="color: purple">If using standards prepared on a previous day compare the trend line equation to ensure that error has not been introduced</span><BR><BR> ===Calculate the Concentration of the Unknown Samples:=== * Use the standard curve equation to calculate the log concentration of your unknown samples (x = log concentration, y = Cp determined by RT-PCR) * Solve the log to calculate the concentrations of the unknowns. Multiply the values calculated by your dilution factor (typically 1000) to obtain the concentration of your sample. == Using RT-PCR Information to Improve Clustering == We utilize the concentrations obtained by RT-PCR to help better control the amount of sample that we are loading onto each flowcell for sequencing. We take these concentrations into account during the denaturation step of cluster generation. 2uL of a 10nM sample will be denatured in 6uL EB and 2uL of 0.5N NaOH for a final volume of 10uL. For samples that are under 10nM: * Adjust sample:EB ratio to allow for proper loading concentration onto each flowcell. If samples are not concentrated enough, you may boil your samples at 98°C for 5min as an alternative to the sodium hydroxide denaturation. For samples over 20nM: * Dilute samples down to 10nM with EB and follow NaOH denaturation recipe above.
Summary:
Please note that all contributions to BioMicro Center may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
BioMicro Center:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Template used on this page:
Template:BioMicroCenter
(
edit
)