Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
BioMicro Center
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
BioMicroCenter:Cluster Visualization Protocol for Flowcell QC
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Special pages
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{BioMicroCenter}} == Cluster Visualization for Flowcell QC == This protocol is a slightly modified version of the protocol supplied by Illumina, and allows for the visualization of clusters on a flowcell before it is put on the Genome Analyzer. It is especially helpful to ensure proper amplification has occurred if there has been a clog or an error on the cluster station or if an older Cluster Generation kit that may be expired is being used. This protocol is to be carried out on the Cluster Station after amplification. == Materials == * SYBR Green mix (We use Roche LightCycler 480 SYBR Master Mix, Cat. No. 04707516001) * Illumina Wash Buffer * Illumina Storage Buffer * Fluorescent microscope equipped with a GFP filter set == Protocol == * Dilute 500uL of SYBR Green in 1500uL Wash Buffer in a 2mL microcentrifiuge tube labeled as #8 and load onto the Cluster Station * Manually prime solution 8x10 and then manually pump the dilute SYBR using the following settings: #Reagent: 8 #Flowrate: 30 #Volume 150 * Remove the Flowcell from the cluster station for observation on the Fluorescent microscope. Use the GFP filter set, blue light. Neutral Denstity filters can be used to help prevent photobleaching '''If amplification was successful and clusters were observed continue with protocol. If clusters were not visualized re-cluster samples on a new Flowcell''' * Place Flowcell back onto Cluster Station * Label a 50mL tube as #10 and fill with about 5mL Wash Buffer. Load #10 onto the Cluster station. * Manually pump #10 using the following settings: #Reagent: 10 #Flowrate: 30 #Volume: 200 * Label a 50mL tube as #12 and fill with about 5mL Storage Buffer. Load #12 onto the Cluster Station. * Manually pump #12 using the following settings: #Reagent: 10 #Flowrate: 30 #Volume: 200 * Remove Flowcell and store at 4C until ready for use * Replace #8 with 1.5mL screw cap tube filled with water * Remove amplification manifold and replace with wash bridge * Was line 8 by manually pumping water using the following settings: #Reagent: 8 #Flowrate: 30 #Volume: 150
Summary:
Please note that all contributions to BioMicro Center may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
BioMicro Center:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Template used on this page:
Template:BioMicroCenter
(
edit
)